See Like Animals Open the tool

Guinea pig vision: the science and the numbers

Cavia porcellus · order Rodentia · Mammals: all the numbers

The guinea pig has 2 colour receptor classes (400 and 530 nm): mainly blues and yellows; reds and greens look alike.[1][2] The guinea pig stops seeing flicker at 47.5 Hz, against 60 Hz for people.[24]

  • 2colour receptor classesMeasured
  • 47.5hertz flicker fusion (motion)Measured*

The guinea pig (Cavia porcellus) is a mammal in the order Rodentia. Its eyes belong to the vision type Small prey mammal (UV): two or three cone types, often including ultraviolet, low sharpness and a near-panoramic field. Measured in this species: colour, foveas, night vision and motion (flicker fusion). Measured core: measured values on at least 3 of the 6 dials.

This is a simulation built from published eye measurements, not what the animal experiences.

What the guinea pig sees: colour receptors

Guinea pig colour receptor peaks, 300 to 700 nmGuinea pig: 2 receptor peaks at 400, 530 nm; you: 3 at 421.5, 532, 558.4 nm. ultraviolet300400500600700
Guinea pig: 400, 530 nmPeople: 421.5, 532, 558.4 nmWavelength in nanometres

What stands out

  • It has two colour receptor classes (a dichromat): reds and greens fall on one axis, as in red-green colour blindness in people.
  • It stops seeing flicker at 47.5 Hz, against 60 Hz for people in this dataset, so fast motion looks choppier to it.[25][26]
  • Activity pattern: cathemeral.

The six dials

Evidence levels: how the tiers work. "Measured" means a value measured in this species; "Estimated" values come from a close relative or an eye-size formula. The last column gives the values for people from the same catalogue.

Vision values for the guinea pig (Cavia porcellus), catalogue-v1
DialValueEvidenceSourcesPeople
ColourColour receptors
2 receptor classes: 400 nm (VS/SWS (violet)), 530 nm (MWS (green))
measured in this species
Measured[1][2]Colour receptors: 3 receptor classes: 421.5 nm (VS/SWS (violet)), 532 nm (MWS (green)), 558.4 nm (LWS (long)) Measured (not re-verified)[1][3][4][5]
SharpnessAcuity
5.8 cycles per degree
median of 1 relatives in family Caviidae: Hydrochoerus hydrochaeris
Estimated[6]Acuity: 63.75 cycles per degree Measured[7][6]
Field of viewBinocular overlap
52°
median of 15 relatives in order Rodentia: Octodon degus, Octodon lunatus, Rattus rattus, Mus musculus, Mesocricetus auratus, Sciurus carolinensis
Group default[8][9][10][11]Binocular overlap: 122.5° Measured[8][9]
Total field of view: 200° Measured (not re-verified)[12]
Blind area behind the head: 160° Derived[12]
Eye placement: frontal Derived[8][9]
Sharp zones (foveas)Number of foveas
0
fovea_present / area_centralis_type (retinal topography; count 1 = fovea present, 0 = none)
Measured[13]Number of foveas: 1 Measured[13]
Fovea type: fovea Measured[13]
Fovea type
horizontal streak
Measured[13]
Night visionActivity pattern
cathemeral
tie ['cathemeral', 'crepuscular'] broken by species-level studies (round-3 tie-break rule 2) (of 6 rows): cathemeral; crepuscular; diurnal; nocturnal
Measured (not re-verified)[14][15][16][1][17][18]Activity pattern: diurnal Measured (not re-verified)[14][15][16][1][17][19][20][18]
Pupil shape: vertical Group default[21][22]
Reflective layer (tapetum): no Measured[23]
Rods vs cones: cone-dominated Derived[14][15][16][1][17][19][20][18]
Rods vs cones
mixed
nocturnal -> rod-dominated; crepuscular / cathemeral / mixed -> mixed; diurnal -> cone-dominated
Derived[14][15][16][1][17][18]
Motion (flicker fusion)Flicker fusion frequency
47.5 Hz
median of 1 bright-light rows (behavioural/whole-eye ERG rows; all rows: [47.5, 50.0])
Measured (not re-verified)[24]Flicker fusion frequency: 60 Hz Measured[25][26]

All mammals side by side: Mammals: every measurement. Method: how we know what animals see.

Sources

  1. Longcore 2023
  2. VPOD in-vivo (MSP / single-cell) lambda… 2025
  3. Kirwan
  4. Müller et al. 2009
  5. Thermal Activation and Photoactivation of Visual… 2004
  6. Veilleux et al. 2014
  7. Kirk et al. 2004
  8. Heesy 2004
  9. Heffner et al. 1992
  10. Vega-Zuniga et al. 2013
  11. Vega-Zuniga et al. 2017
  12. Campbell & Green 1965
  13. Kopania et al. 2025
  14. Anderson et al. 2017
  15. Borges et al. 2018
  16. Wilman et al. 2014
  17. Maor et al. 2017
  18. Moura et al. 2024
  19. Jones et al. 2009
  20. Schmitz et al. 2011
  21. Banks et al. 2015
  22. Cervino et al. 2021
  23. Guareschi et al. 2025
  24. Lafitte et al. 2022
  25. Healy et al. 2013
  26. Inger et al. 2014

Every value cites its sources (all sources). Values were extracted from these works and converted (units, medians, derived values); changes are ours, and the listed sources do not endorse this site. Data: catalogue-v1, built 2026-09-29. Accuracy notes: how accurate is this? Method: how we know.